{"id":41,"date":"2011-12-03T08:29:31","date_gmt":"2011-12-03T08:29:31","guid":{"rendered":"http:\/\/presizion.com.tr\/en\/?page_id=41"},"modified":"2011-12-13T12:01:58","modified_gmt":"2011-12-13T12:01:58","slug":"pnm-pne-registers","status":"publish","type":"page","link":"http:\/\/presizion.com.tr\/en\/products\/flow-meters\/pnm-pne-registers\/","title":{"rendered":"PNM &#8211; PNE Registers"},"content":{"rendered":"<p>[tab:PNM Series Mechanical Registers]<\/p>\n<ul>\n<li><span style=\"background-color: #e5e5e5;\"><strong>PNM Series Mechanical Registers<\/strong><\/span><\/li>\n<\/ul>\n<div>\n<p>PNM series mechanical registers are recorders enabling mechanical reading of amount of liquid fuel passing through flow meters. Number of digits on dial which is resettable is five (5) and number of digits on totalizer which is resettable is seven (7).<\/p>\n<\/div>\n<p style=\"text-align: center;\"><span style=\"font-size: xx-small;\"><em>* Click to enlarge<a href=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/MNumarator.jpg\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-222\" title=\"MNumarator\" src=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/MNumarator-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" \/><\/a><\/em><\/span><\/p>\n<p><strong>&gt; Technical Specifications<\/strong><\/p>\n<p><a href=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/MNumaratorTablo.jpg\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" title=\"MNumaratorTablo\" src=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/MNumaratorTablo.jpg\" alt=\"\" width=\"619\" height=\"131\" \/><\/a><br \/>\n[tab:PNE Series Electronic Registers]<\/p>\n<ul>\n<li><span style=\"background-color: #e5e5e5;\"><strong>PNE Series Electronic Registers<\/strong><\/span><\/li>\n<\/ul>\n<div>PNE series electronic registers are recorders enabling digital reading and control of amount of liquid fuel passing through flow meters.<\/div>\n<p style=\"text-align: center;\"><span style=\"font-size: xx-small;\"><em>* Click to enlarge<\/em><\/span><\/p>\n<p style=\"text-align: left;\"><span style=\"font-size: xx-small;\"><em><a href=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/ENumarator.jpg\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-224\" title=\"ENumarator\" src=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/ENumarator-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" \/><\/a><\/em><\/span><\/p>\n<p style=\"text-align: left;\"><strong>&gt; Standard Features<\/strong><\/p>\n<table width=\"614\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>12 &#8211; 24 V DC<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Automatic error detection and warning<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Liter\/Gallon reading<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Five (5) level password protect<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Automation access<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Printer support<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>100 gr accuracy reading range<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Real-time clock<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Compatible with automation systems<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Identification (product names, prices,\u00a0ATC factors, electronic\u00a0total Etc.)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Liter or amount(money) presets availability<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>To view historical information\u00a0(recent sales, recent errors, prices)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Instantaneous flow rate readability<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Language support (Turkish &#8211; English)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Nine (9) digit electronic totalizer<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Valve control over flow meter<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"307\">\n<ul>\n<li>Automatic temperature compensation (ATC)<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"307\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\"><strong style=\"text-align: -webkit-auto;\">&gt; Technical Specifications<\/strong><\/p>\n<p><a href=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/ENumaratorTablo.jpg\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" title=\"ENumaratorTablo\" src=\"http:\/\/presizion.com.tr\/tr\/wp-content\/uploads\/ENumaratorTablo.jpg\" alt=\"\" width=\"625\" height=\"130\" \/><\/a>[tab:END]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[tab:PNM Series Mechanical Registers] PNM Series Mechanical Registers PNM series mechanical registers are recorders enabling mechanical reading of amount of liquid fuel passing through flow meters. Number of digits on dial which is resettable is five (5) and number of digits on totalizer which is resettable is seven (7). * Click to enlarge &gt; Technical [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":17,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-41","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/pages\/41","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/comments?post=41"}],"version-history":[{"count":4,"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/pages\/41\/revisions"}],"predecessor-version":[{"id":175,"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/pages\/41\/revisions\/175"}],"up":[{"embeddable":true,"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/pages\/17"}],"wp:attachment":[{"href":"http:\/\/presizion.com.tr\/en\/wp-json\/wp\/v2\/media?parent=41"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}